KONICA MINOLTA AeroDR
DR solutions featuring lightweight DR detectors and lower dose imaging
DR solutions featuring lightweight DR detectors and lower dose imaging
Send patient images to PACS
Obtain examination information from RIS and send back each result
Link up x-ray exposure condition with x-ray console
Write patient image on CD/DVD with DICOM, PDI, and JPEG format
Quick image preview in under 2 seconds
User-friendly graphical user interface (GUI) adding new and powerful proprietary functions
Easily modify GUI to meet customer preferences and flexibility needs
Intelligent Grid Function improves contrast which is affected by scattered radiation without a grid. This provides easy workflow and does not require the operator to carry the grid to perform an exam
Highlight Function can highlight tube/gauze in images that are difficult to be detected in normal images
Stitching Function can combine 2 or 3 images and also can adjust the combined position of images on the screen. This function is useful at handling long images as 1 image
The lightest FPD in the world (as of 2013), weighs only 1.7Kg including batteries. It is an ideal solution for exams such as pediatric or extremities
World’s Lightest Weight (including battery) (2.9kg) This 14 x 17 in (35 x 43 cm) Cesium Iodide detector is easy to handle making it especially convenient for multi-room use
The most lightweight (3.6Kg) 17 x17 in (43 x 43 cm) panel, despite being cassette size and wireless. The larger image area allows more anatomy to be imaged, thereby reducing positioning errors
Konica Minolta succeeded by creating a new technology whereby a CsI scintillator is made to contact directly over a TFT*1 sensor panel without any protective layer in between them. This technology has made it possible to guide the light emitted from the scintillator to the photodiode without causing the light to be dispersed at the interface with the TFT sensor.
The DR QC Phantom allows comprehensive quality assurance testing for DR Detectors and associated software. The phantom enables seven quality assurance assessments for monthly and semi-annual evaluation, including exposure linearity and sensitivity, high and low contrast reproducibility, artifact and residual image detection, image resolution, collimator beam alignment, measurement tool accuracy, and display jitter QA testing.
Detectors
Detectors | 1012HQ | 1417HQ | 1717HQ |
---|---|---|---|
Detector Size | 10 X 12 in (24 x 30 cm) | 14 x 17 in (35 x 43 cm) | 17 x 17 in (43 x 43 cm) |
Scintillator | Cesium Iodide (CsI) | Cesium Iodide (CsI) | Cesium Iodide (CsI) |
Active Area | 9.7 x 11.7 in | 13.7 x 16.7 in | 16.7 x 16.7 in |
Pixel Matrix | 1404 x 1696 | 1996 x 2434 | 2428 x 2428 |
Pixel Pitch | 175 μm | 175 μm | 175 μm |
Bit Depth (A/D) | 16 bit A/D | 16 bit A/D | 16 bit A/D |
Image Display | less than 4 seconds | less than 4 seconds | less than 4 seconds |
Cycle Time | 7-9 seconds | 8-12 seconds | 8-14 seconds |
Limiting Resolution | 3.5 lp/mm | 3.5 lp/mm | 3.5 lp/mm |
Dimensions | 11.1 x 13.1 x 0.63 in | 15.1 x 18.1 x 0.63 in | 18.1 x 18.1 x 0.63 in |
Weight | 3.75 lbs | 6.4 lbs | 7.9 lbs |
CS-7 Control Station
DICOM Services | DICOM Storage SCU DICOM Print SCU DICOM Modality Worklist Management DICOM Storage Commitment SCU |
---|---|
Maximum Resolution | – Up to 2 DICOM Store Plus 1 Backup – Up to 1 DICOM Print Plus 1 Backup |
Image Processing | Automatic gradation processing (G processing) Frequency processing (F processing) Equalization processing (E processing) Hybrid processing (H processing) |
Image Storage Capacity | Approximately 5,000 images |