OTC18M
Premium overhead tube crane system with LCD touchscreen
Premium overhead tube crane system with LCD touchscreen
The OTC18M tube crane highlights an advanced, technologist friendly 10.4 in touchscreen console that provides seamless system integration by displaying tube angulation, SID values, and generator control options. Color-coded movement identification buttons provide optimal precision when setting up views. Peaceful and effortless movements are controlled by an electromagnetic braking system enabling fast and secure readjustments of the tube head. Its five-tier telescoping column delivers exceptional vertical movement of 71 in (180 cm), capable of performing complete head-to-toe radiographic procedures including upright weight-bearing and recumbent tabletop exams.
A conveniently placed all-lock release sensor is located just above the bottom section of the tube head handle. This sensor enables rapid manual positioning by allowing the user to grab the bottom handle to unlock the system and make swift adjustments.
Accelerates patient positioning and reduces radiation exposure by automatically selecting the proper field-of-view for each body part. This feature is available through the DELWORKS DR acquisition software’s pre-programmed APR settings.
The durable EV800 elevating four-way float top table delivers outstanding safety and usability. Featuring an exclusive four-point lift system and exceptionally quiet motor-drive, its smooth, scratch-resistant tabletop lowers to a height of just 22 in to ensure stress-free patient transfers and adjustments. Offering a high patient weight capacity of up to 800 lbs (363 kg), stable continuous movement is possible through conveniently placed recessed foot treadles and table-side controls, suitable for increasing technologist performance and satisfaction.
The VT300 wall stand features a tilting image receptor, promoting comfort and precision for standing or seated examinations. Every adjustment is precisely counterbalanced to allow smooth operation with light effort applied by the technologist. This makes the VT300 accommodating to all users regardless of size or strength.
The easy-to-use rotating tray enables manual rotation of the DR detector. The stable one-handed operation supports fast portrait-to-landscape positioning without ever removing the detector from the tray. Fully extended steel slides activate locking mechanisms to assure detector protection when loading and unloading — designed to accommodate a wide array of ISO 14 x 17 in (35 x 43 cm) cassette-sized detectors.
OTC18M Tube Crane
Room Height | 105 – 119 in (267 – 302 cm) |
---|---|
Room Height (with Optional Telescopic Extension) | 105 – 127 in (267 – 322 cm) |
Vertical Telescopic Travel Range | 70.8 in (180 cm) with minimum 32.7 in (83 cm) focal spot to ceiling distance / 15.5 in (39.4 cm) focal spot to floor distance with a 9 ft ceiling height |
Longitudinal Travel Range | Standard: 14 ft rail included, 136.2 in (346 cm) min Optional: rail extensions: 219.9 in (558.5 cm) max |
Transverse Travel Range | Standard: 10 ft bridge with 9.8 ft transverse carriage: 86.6 in (220 cm) min Optional: 13 ft bridge with 13.1 ft transverse carriage: 139.7 in (355 cm) max |
Longitudinal Detent Positions | Configurable during installation |
Tube Rotation Range (Horizontal Axis) | -120°, +120°, Detent positions at -90°, 0°, +90° |
Tube Rotation Range (Vertical Axis) | -182°, +154°, Detent positions at -180°, -90°, 0°, +90° |
Weight (with Collimator and Tube) | 507 lbs (230 kg) |
Power Requirements | 100-240 VAC 50/60 Hz, 3.6 Amps |
EV800 Elevating Table
Patient Load Capacity | 800 lbs (363 kg) |
---|---|
Table Base Length | 53 in (135 cm) |
Table Base Width | 25 in (64 cm) |
Total Tabletop Movement | Longitudinal ±19.75 in (50 cm) Transverse ±6.5 in (16.5 cm) |
Variable Height | 22.25 – 34.25 in (56.5 – 87 cm) |
Total Bucky Travel | ±8.5 in (22 cm) |
Tabletop-to-film Distance | 3.2 in (8 cm) 2.7 in (6.9 cm) upper position for special applications |
Tabletop Beam Attenuation | Standard: less than 0.7 mm aluminum Carbon fiber: less than 0.4 mm aluminum |
Tabletop Length | 86.5 in (220 cm) |
Tabletop Width | 36 in (91 cm) |
Weight | 563 lbs (256 kg) |
Power Requirements | 120 / 230-240 VAC 50 / 60 Hz 10 Amps |
Options | – 78 in (198 cm) tabletop length / 32 in (81 cm) tabletop width – Carbon fiber – Lateral cassette holder – Table-side patient handgrips – Table-side hand controls – Compression band – Grids – Grid cabinet – Reciprocating bucky – Size sensing tray – Rotating cassette tray – AEC |
VT300 Tilting Wall Stand
Receptor Tilt Range | +90°/ 20° |
---|---|
Vertical Travel Range, Vertical Receptor | 15.5 – 71.1 in (39.4 – 180.6 cm) |
Vertical Travel Range, +90° Receptor | Minimum 25.5 in (64.8 cm) |
Height | 82.24 in (211 cm) |
Depth, Vertical Receptor | 30 in (76 cm) |
Receptor Width | 27.25 in (69.2 cm) |
Receptor Height | 26.5 in (67.3 cm) |
Front Panel Aluminum Equivalency | 0.4 mm |
Weight | 765.5 lbs (347.2 kg) |
Weight (without Counterweights) | 368.5 lbs (167 kg) |
Power Requirements | 120/230-240 VAC 50/60 Hz |
Options | – 8 in (20 cm) extension box extends receptor from the column, enabling supine exams – Variety of grid options – Grid cabinet – Reciprocating bucky – Size sensing tray – Rotating tray – Left or right sideload – AEC – Vertical auto-tracking with OTC18T |
OTC18M Tube Crane | |
---|---|
Room Height | 105 – 119 in (267 – 302 cm) |
Room Height (with Optional Telescopic Extension) | 105 – 127 in (267 – 322 cm) |
Vertical Telescopic Travel Range | 70.8 in (180 cm) with minimum 32.7 in (83 cm) focal spot to ceiling distance / 15.5 in (39.4 cm) focal spot to floor distance with a 9 ft ceiling height |
Longitudinal Travel Range | Standard: 14 ft rail included, 136.2 in (346 cm) min Optional: rail extensions: 219.9 in (558.5 cm) max |
Transverse Travel Range | Standard: 10 ft bridge with 9.8 ft transverse carriage: 86.6 in (220 cm) min Optional: 13 ft bridge with 13.1 ft transverse carriage: 139.7 in (355 cm) max |
Longitudinal Detent Positions | Configurable during installation |
Tube Rotation Range (Horizontal Axis) | -120°, +120°, Detent positions at -90°, 0°, +90° |
Tube Rotation Range (Vertical Axis) | -182°, +154°, Detent positions at -180°, -90°, 0°, +90° |
Weight (with Collimator and Tube) | 507 lbs (230 kg) |
Power Requirements | 100-240 VAC 50/60 Hz, 3.6 Amps |
EV800 Elevating Table | |
---|---|
Patient Load Capacity | 800 lbs (363 kg) |
Table Base Length | 53 in (135 cm) |
Table Base Width | 25 in (64 cm) |
Total Tabletop Movement | Longitudinal ±19.75 in (50 cm) Transverse ±6.5 in (16.5 cm) |
Variable Height | 22.25 – 34.25 in (56.5 – 87 cm) |
Total Bucky Travel | ±8.5 in (22 cm) |
Tabletop-to-film Distance | 3.2 in (8 cm) 2.7 in (6.9 cm) upper position for special applications |
Tabletop Beam Attenuation | Standard: less than 0.7 mm aluminum Carbon fiber: less than 0.4 mm aluminum |
Tabletop Length | 86.5 in (220 cm) |
Tabletop Width | 36 in (91 cm) |
Weight | 563 lbs (256 kg) |
Power Requirements | 120 / 230-240 VAC 50 / 60 Hz 10 Amps |
Options | – 78 in (198 cm) tabletop length / 32 in (81 cm) tabletop width – Carbon fiber – Lateral cassette holder – Table-side patient handgrips – Table-side hand controls – Compression band – Grids – Grid cabinet – Reciprocating bucky – Size sensing tray – Rotating cassette tray – AEC |
VT300 Tilting Wall Stand | |
---|---|
Receptor Tilt Range | +90°/ 20° |
Vertical Travel Range, Vertical Receptor | 15.5 – 71.1 in (39.4 – 180.6 cm) |
Vertical Travel Range, +90° Receptor | Minimum 25.5 in (64.8 cm) |
Height | 82.24 in (211 cm) |
Depth, Vertical Receptor | 30 in (76 cm) |
Receptor Width | 27.25 in (69.2 cm) |
Receptor Height | 26.5 in (67.3 cm) |
Front Panel Aluminum Equivalency | 0.4 mm |
Weight | 765.5 lbs (347.2 kg) |
Weight (without Counterweights) | 368.5 lbs (167 kg) |
Power Requirements | 120/230-240 VAC 50/60 Hz |
Options | – 8 in (20 cm) extension box extends receptor from the column, enabling supine exams – Variety of grid options – Grid cabinet – Reciprocating bucky – Size sensing tray – Rotating tray – Left or right sideload – AEC – Vertical auto-tracking with OTC18T |